// Wiring & Networks
Intermittent Electrical Faults: How to Catch a Fault That Isn't There
Published by DiagEdge · 19 November 2026 · 7 min read
Intermittent faults are the ones that drive technicians and customers mad: the light comes and goes, the car runs perfectly in the workshop, and nothing is wrong when you test it. The trick is to stop testing when the fault isn't present, and instead recreate it or capture it when it is.
1. Use what the car already recorded
- Freeze-frame data is a snapshot of conditions at the moment a code set: speed, RPM, load, coolant temperature, fuel trims. It tells you whether the fault happens cold or hot, at idle or at speed, and lets you recreate those conditions.
- History and pending codes across all modules can show a pattern — several modules logging communication faults at the same time points to a shared power, ground or network problem, not each module.
- Ask the customer exactly when it happens: cold mornings, over bumps, in rain, when a particular accessory is on.
2. Recreate the conditions
Most intermittent faults are triggered by heat, cold, vibration or moisture:
- Heat: warm a suspect component or connector with a heat gun (carefully).
- Cold: use freeze spray on a component — a sudden failure points at it.
- Moisture: spray water around connectors and harness routes (carefully, away from ignition components).
- Vibration: the wiggle test, below.
3. The wiggle test
With the circuit live, connect a scope (in long "roll" mode) or a scan-tool graph to the signal, power or ground you suspect. Then flex the harness and connectors section by section along its route. A spike or drop-out on the trace as you move one section tells you exactly where the fault is.
Pay attention to places where the harness moves or rubs: through door hinges, around the engine mounts, across the gearbox and where it's clipped to the body.
4. Voltage drop beats ohms
A resistance test with a multimeter puts a tiny current through the wire. A connection with a few broken strands, or a corroded terminal, can read perfectly — then fail as soon as real current flows. Measure voltage drop with the circuit loaded instead: a meaningful voltage across a wire or connection that should have almost none means resistance in that path.
5. Check terminal fit
Many intermittent faults are just a loose terminal. With a matching terminal-test probe, check each pin in the connector grips firmly. A terminal that's spread or corroded can make contact when still and lose it with vibration. Look for green corrosion, pushed-back pins and water inside connectors.
6. Log data on a road test
If you can't make it happen in the workshop, record it. Set the scan tool to log the relevant data (or use a scope with a long capture) and drive until the fault appears. When it does, the log shows what changed first — and that's usually your culprit.
Fix the cause, not just the symptom
Once you've found the fault, find out why it happened. A chafed harness will chafe again if it isn't re-routed and protected; a corroded connector needs the water source fixed as well as the terminal.
Stuck on a fault like this?
DiagEdge gives every technician AI-powered diagnostic guidance across six specialist modules. First month just A$1.
Start for A$1 today