Intermittent faults are the ones that drive technicians and customers mad: the light comes and goes, the car runs perfectly in the workshop, and nothing is wrong when you test it. The trick is to stop testing when the fault isn't present, and instead recreate it or capture it when it is.

1. Use what the car already recorded

2. Recreate the conditions

Most intermittent faults are triggered by heat, cold, vibration or moisture:

3. The wiggle test

With the circuit live, connect a scope (in long "roll" mode) or a scan-tool graph to the signal, power or ground you suspect. Then flex the harness and connectors section by section along its route. A spike or drop-out on the trace as you move one section tells you exactly where the fault is.

Pay attention to places where the harness moves or rubs: through door hinges, around the engine mounts, across the gearbox and where it's clipped to the body.

4. Voltage drop beats ohms

A resistance test with a multimeter puts a tiny current through the wire. A connection with a few broken strands, or a corroded terminal, can read perfectly — then fail as soon as real current flows. Measure voltage drop with the circuit loaded instead: a meaningful voltage across a wire or connection that should have almost none means resistance in that path.

5. Check terminal fit

Many intermittent faults are just a loose terminal. With a matching terminal-test probe, check each pin in the connector grips firmly. A terminal that's spread or corroded can make contact when still and lose it with vibration. Look for green corrosion, pushed-back pins and water inside connectors.

6. Log data on a road test

If you can't make it happen in the workshop, record it. Set the scan tool to log the relevant data (or use a scope with a long capture) and drive until the fault appears. When it does, the log shows what changed first — and that's usually your culprit.

Fix the cause, not just the symptom

Once you've found the fault, find out why it happened. A chafed harness will chafe again if it isn't re-routed and protected; a corroded connector needs the water source fixed as well as the terminal.